4. Do one of the following:

To configure a static Ethernet configuration, type the following commands:

-> set pendingipdiscovery=static -> set pendingipaddress=xxx.xxx.xx.xx

-> set pendingipnetmask=yyy.yyy.yyy.y -> set pendingipgateway=zzz.zzz.zz.zzz

-> set commitpending=true

where xxx.xxx.xx.xx, yyy.yyy.yyy.y and zzz.zzz.zz.zzz are the IP address, netmask, and gateway for your ILOM and network configuration. To determine these addresses, see your system administrator.

To configure a dynamic Ethernet configuration, type the following commands:

-> set pendingipdiscovery=dhcp -> set commitpending=true

5.To log out of ILOM, type:

-> exit

If you connected to the server module ILOM through the CMM ILOM, you will be returned to the CMM ILOM.

If you connected to ILOM using SSH, you will be disconnected automatically because you logged in under a different IP address. If it is taking a long time to be disconnected, you can force a disconnect by typing ~. in the SSH window.

The following display shows a typical session where the user looks at static settings, configures them to be dynamic, then looks at the new settings.