Sun Microsystems X6240 manual Using your Solaris server, log in and start Xserver

Models: X6240

1 72
Download 72 pages 36.37 Kb
Page 54
Image 54

Creating a RAID Set to Incorporate a Preinstalled OS Using the Sun StorageTek REM Card

The Sun StorageTek REM card enables you to choose from many RAID configurations. How you configure your system depends on your system requirements and the available hard disk drives in the system.

This procedure describes how to mirror the preinstalled Solaris OS. This is the better option, and all remaining disks (should there be more than 2) are incorporated into a DATA RAID set using the available options as shown in TABLE 3-3.

You will need the Sun Blade X6240 Server Module Tools & Drivers CD (707-0257).

To Incorporate a Preinstalled Solaris OS Using the Sun StorageTek REM Card

Follow these steps to mirror your configured Solaris OS:

1.Using your Solaris server, log in and start Xserver.

This graphical user interface is required for StorageTek Software Management.

2.Make a new directory on your Solaris server, type: mkdir /StorMan

3.Insert the supplied Tools & Drivers CD, and copy the StorMan.dss application, located in the /mount-point/RAIDmgmt/StorageTEK/Solaris directory, to the new directory you created on your Solaris server, for example, /StorMan.

4.Change the permissions of the new directory and StorMan application, type: chmod 777 StormMan.dss

5.Run the following command to install the application: pkgadd -d StorMan.dss

6.Choose to install all components when prompted.

7.To run the application, type the following: sh /usr/StorMan/StorMan.sh

A split screen appears.

42 Sun Blade X6240 Server Module Installation Guide • June 2008