RAID Drive Options

TABLE 3-3shows the RAID drive options.

TABLE 3-3RAID Drive Options

REM Card

Drives Supported

RAID Configuration Supported

Drive Usage

 

 

 

 

Sun StorageTek Seagate 73GB SAS

Fujitsu 73GB SAS

Seagate 146GB SAS

Fujitsu 146GB SAS

Hitachi 146GB SAS

Fujitsu 200GB SATA

LSI 3081E

Seagate 73GB SAS

 

Fujitsu 73GB SAS

 

Seagate 146GB SAS

 

Fujitsu 146GB SAS

 

Hitachi 146GB SAS

 

Fujitsu 200GB SATA

Volume – 1 disk

 

RAID 0 – stripe – 2 disk minimum

No redundancy

RAID 1 – mirror – 2 disk minimum

50%

RAID 1E – 3 drive minimum

50%

RAID 5 – 3 drive minimum

67–94%

RAID 5EE – 4 drive minimum

50–88%

RAID 50 – 6 drive minimum

67–94%

RAID 6 – 4 drive minimum

50–88%

RAID 60 – 8 drive minimum

50–88%

Spanned Volume – 2 drive minimum

100%

RAID Volume – 4 drive minimum

50-100%

IM (Integrated Mirror array) – 2 disk

Data on Primary disk

minimum, plus up to 2 hot spare disks.

might be merged.

IME (Integrated Mirror Enhanced array) –

All data will be deleted

3 to 8 disks including up to 2 hot spares.

during creation.

IS (Integrated Striping array) – 2 to 8

All data will be deleted

disks.

during creation.

Mirroring the Preinstalled Solaris OS with LSI RAID

The Solaris OS supports hardware RAID and cannot be installed on an existing array if one has been created. Refer to the Sun Blade X6240 Server Module OS Installation Guide (820-3969) or a REM card product guide.