Sun Microsystems X6240 manual Type the reset command, To navigate to /SP/network, type

Models: X6240

1 72
Download 72 pages 36.37 Kb
Page 38
Image 38

b. Type the reset command:

-> reset /SP

DHCP automatically assigns ILOM an IP address when the server module restarts.

5.Find the IP address that DHCP assigned to the server module ILOM.

See Step 8 in “To Configure the ILOM IP Address Using BIOS Setup Utility” on page 23.

To Configure the ILOM IP Address Using the CLI

This procedure describes how to manually configure the ILOM IP address using the CLI.

1. Connect to the server module ILOM using one of the following methods:

Connect to the server module ILOM using the chassis serial connector as described in “Option 1: Connecting to ILOM Through the Chassis Serial Connector” on page 14.

Connect to the server module ILOM using a dongle cable as described in “Option 2: Connecting to ILOM Through a Dongle Cable” on page 18.

Connect to the server module ILOM using SSH as described in “Option 3: Connecting to ILOM Through the Ethernet Port” on page 19.

2.To see the IP address, type show /SP/network/ipaddress. The last string, /ipaddress , is optional.

->show /SP/network/ipaddress

/SP/network

Targets:

Properties:

ipaddress = 10.6.153.148

Commands: show

->

3.To navigate to /SP/network, type:

-> cd /SP/network

26 Sun Blade X6240 Server Module Installation Guide • June 2008