Environmental Requirements

TABLE 1-3gives the environmental requirements for the Sun Blade X6270 Server Module.

TABLE 1-3Sun Blade X6270 Server Module Environmental Requirements

Condition

Requirement

 

 

Operating temperature

5 oC to 35 oC noncondensing

Nonoperating

-40 oC to 65 oC

temperature

 

Operating humidity

10% to 90% noncondensing (27 oC max. wet bulb)

Nonoperating humidity

93% noncondensing (38 oC max. wet bulb)

Operating altitude

3048 meters at 35 oC

Nonoperating altitude

12,000 meters

 

 

Server Module Installation Task Checklist

TABLE 1-4summarizes an ordered list of tasks that you must perform to properly install the server module into a Sun Blade 6000 or 6048 Series Modular System.

TABLE 1-4Installation Task Checklist

Step

Task Description

For Instructions, See:

 

 

 

1Unpack the Sun Blade X6270 Server Module and any optional components ordered for the server from the shipping containers.

2If applicable, install the optional server module components prior to installing the server module into the chassis.

3Install the server module into a powered-on Sun Blade 6000 or 6048 Series Chassis.

4Verify the power state of the server module and apply main power to the server module SP and host.

Chapter 1 “About Your Server Module Shipment” on page 1

Chapter 2 “Install Server Module Optional Components” on page 7

Chapter 3 “Installing and Powering On the Sun Blade X6270 Server Module” on page 33

Chapter 3 “Installing and Powering On the Sun Blade X6270 Server Module” on page 33

4 Sun Blade X6270 Server Module Installation Guide • December 2009

Page 16
Image 16
Sun Microsystems X6270 manual Server Module Installation Task Checklist, Environmental Requirements