TABLE 4-1IP Address Configuration Tasks (Continued)

Step Requirement Description

4Log in to ILOM. Follow instructions in this chapter to log in to ILOM. See “Logging In to ILOM” on page 47.

5

Configure an IP

Follow the instructions in this chapter to initially configure an

 

address.

IP address: see “Configuring an IP Address” on page 49.

6

If applicable,

For more information about configuring or modifying an IP

 

obtain

address in ILOM, refer to the Sun Integrated Lights Out Manager

 

additional

2.0 User’s Guide or the Integrated Lights Out Manager 3.0

 

information

Documentation Collection.

 

about ILOM.

 

 

 

 

Logging In to ILOM

This section presents the following procedures:

“Log In to ILOM Using a Serial Connection” on page 47

“Log In to ILOM From an Ethernet Connection Using the CLI” on page 48

Log In to ILOM Using a Serial Connection

1.Verify that your serial console connection to the server module or CMM is secure and operational.

2.Ensure that the following serial communication settings are configured.

8N1: eight data bits, no parity, one stop bit

9600 baud (default, can be set to any standard rate up to 57600)

Disable hardware flow control (CTS/RTS)

3.Press Enter to establish a connection between your serial console and ILOM. A login prompt to ILOM appears.

Chapter 4 Setting Up ILOM

47

Page 59
Image 59
Sun Microsystems X6270 manual Logging In to Ilom, Log In to Ilom Using a Serial Connection