TABLE 2-3DIMM Classification Labels

Rank Classification

Label

 

 

Quad-rank DIMM

4Rx4

Dual-rank DIMM

2Rx4

Single-rank DIMM

1Rx4

 

 

Install DIMMs

1.Remove the cover from the server.

See “Remove Cover From Server” on page 11.

2.Remove the DIMM filler panel.

See “Remove or Insert Filler Panels” on page 12.

3.To install a DIMM, do the following:

a.Determine the DIMM socket location to populate. See “DIMM Population Rules” on page 16.

b.Ensure that the DIMM ejector levers are open (angled outward). See ejector lever position in FIGURE 2-4.

c.Align the DIMM notch to the DIMM connector key.

d.Using both thumbs, press the DIMM straight down into the DIMM connector slot until both ejector levers close, locking the DIMM in the socket.

Note – The DIMM must be inserted evenly, straight down into the DIMM connector slot, until the ejector levers lock into place.