a.Install the top cover.

See “Install Cover on Server” on page 11.

b.Install the server into the rack.

See “Installing and Powering On the Sun Blade X6270 Server Module” on page 33.

c.Reconnect the power cord (or cords) to the power supply (or supplies) and power on the server.

See “Installing and Powering On the Sun Blade X6270 Server Module” on page 33.

Verify that the AC Present LED is lit.

Adding a CompactFlash Module

The Sun Blade X6270 Server Module is not shipped with the compact flash module option installed. This option must be ordered and is shipped separately for customer installation.

Refer to the following procedure when adding a compact flash module option to the Sun Blade X6270 Server Module.

Install CompactFlash Module

1.Remove the cover from the server.

See “Remove Cover From Server” on page 11.

2.Locate the CompactFlash module slot on the motherboard.

Note – If a RAID expansion module (REM) is installed, the CompactFlash slot is located underneath the REM board.

For CompactFlash location on motherboard, see “Sun Blade X6270 Server Module Option Locations” on page 8.

3.To install the CompactFlash module, do the following:

a.Locate the keys on the side of the compact flash card and align them with the sides of the CompactFlash slot.

See FIGURE 2-6.

b.Slide the compact flash card into the slot until it locks into place.

22 Sun Blade X6270 Server Module Installation Guide • December 2009

Page 34
Image 34
Sun Microsystems X6270 manual Adding a CompactFlash Module, Install CompactFlash Module, Install the top cover