Units are shipped to the customer with no jumper installed. The jumper is used by Symmetricom technicians to test and configure the unit. With this jumper installed, the operation and integrity of the XLi are compromised.

Warning: Please do not run the XLi with the jumper, unless specifically directed to do so by a qualified Symmetricom technician.

To test the state of the factory mode jumper:

F100<S>J<CR>

where:

F= ASCII character F

100= unit function number <S> = space

J= specify User Name command <CR> = input line terminator

The XLi responds:

F100 J FACTORY MODE=1<CR><LF>

or

F100 J FACTORY MODE=0<CR><LF>

F100 K I L L – Reboot

Use function F100 K I L L to reboot the unit. Use F100 K I L L after upgrading the system firmware.

K I L L is a case-sensitive command. When entering this command, use all capital letters and put spaces between each letter.

To reboot the unit, enter:

F100 K<S>I<S>L<S>L<CR>

For example:

F100 K I L L<CR>

XLi responds:

OK <CR><LF>

RESETING THE UNIT<CR><LF>

PLEASE WAIT…<CR><LF>