For example, enter:

F100 IP 206.54.0.21<CR>

XLi responds:

OK<CR><LF>

RESETING THE UNIT<CR><LF>

PLEASE WAIT…<CR><LF>

To obtain the IP address of the unit Standard network port, enter:

F100 IP<CR>

The XLi responds (example):

F100 IP 206.54.0.21<CR><LF>

The three commands, F100 IP, F100 SM, and F100 G, can be concatenated to set all three values simultaneously. To do so use the following format:

F100<S>IP<S><nnn.nnn.nnn.nnn><S>SM<S><nnn.nnn.nnn.nnn><S>G<S><nnn.nnn.nnn.nnn><CR>

Note: The three commands (i.e., IP, SM, G) can be used in any order relative to each other. A colon separator “:” can be used instead of <S> following IP, SM, and G (e.g., IP:192.168.46.150)

For example, using appropriate values for your network, enter something similar to:

F100 IP 192.169.46.150 SM:255.255.255.0 G 192.168.46.1<CR>

XLi responds:

OK<CR><LF>

RESETING THE UNIT<CR><LF>

PLEASE WAIT…<CR><LF>

F100 SM – Subnet Mask

Note: F100 SM can be used concurrently with F100 IP and F100 G. See the last example provided in the F100 IP – IP Address section, directly above this one.

Use function F100 SM to display or configure the Subnet Mask. To set the Subnet Mask and restart the unit, enter:

F100<S>SM<S><nnn.nnn.nnn.nnn><CR>