SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS

F117 – Factory Configuration

Note: The standard XLi IEEE 1588 clock includes the TIET option as a standard feature. The other optional software features, NTP, FREQ MEAS, and PPO, are unavailable for the standard XLi IEEE 1588 clock.

Use function F117 to display the XLi factory Serial Number and the availability of optional software features. Send the string:

F117<CR>

XLi responds:

F117<S>SN<S><SERIAL#><CR><LF>

NTP <STATE><CR><LF>

FREQ MEAS <STATE><CR><LF>

TIET <STATE><CR><LF>

PPO <STATE><CR><LF>

where:

F= ASCII character F.

117 = function number.

<S>

=

ASCII space character one or more.

NTP

=

NTP option

FREQ MEAS =

FREQ MEAS option

TIET

=

TIET option

PPO

=

PPO option

<CR>

=

carriage return.

<STATE>

=

ENABLE or DISABLE

<LF>

=

line feed.

For example, enter:

F117<CR>

XLi responds:

F117 SN 31234<CR><LF>

NTP ENABLE<CR><LF>

FREQ MEAS ENABLE<CR><LF>

TIET ENABLE<CR><LF>

PPO ENABLE<CR><LF>

XLi IEEE 1588 Clock

107

997-01510-03, Rev. C, 12/12/2006

Page 115
Image 115
Symmetricom XLi IEEE 1588 manual F117 Factory Configuration, F117CR, Ntp, Freq Meas =, Ppo