SSSSSS

S

SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS

where:

 

 

F

=

ASCII character F

131

=

Unit function number

<SP>

= Space

B

= ASCII letter to denote Option Bay number follows

<N>

=

Option Bay Number, 1 through 4.

SDN

= Specify subdomain name command.

SUBDOMAIN

= Specify one of the following:

 

 

_DFLT, _ALT1, _ALT2, _ALT3

For example, enter:

F131 B4 SDN _ALT1

Response (example):

>f131 b4 sdn _ALT1

OK - The Subdomain Name been received and applied by the PTP Option Card

Reset the PTP Parameters to the Factory Default settings

To reset the PTP parameters to the factory default settings, use the following format:

F131 B<N> RFD<CR>

For example, enter:

F131 B4 RFD

Response (one of the following lines):

OK - The PTP Option Card Network Port has been set to Factory Default values<CR><LF>

Initialize the PTP Protocol to User-entered Values

Each time the user changes any PTP setting using F131, the user must enter this command for the changes to take effect.

To initialize the PTP Protocol to user-entered values, use the following format:

F131 B<N> INIT<CR>

For example, enter:

F131 B4 INIT

XLi IEEE 1588 Clock