SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS

The factory settings for F90 are IRIG-B and AM.

Although the factory configuration outputs UTC time in 24-hour format, the following can be used to modify the code output of F90 for non-standard applications:

“F2 – 12/24 Hour Format” on page 39 selects between a 12 or 24-hour time format.

“F69 – Time Mode” on page 65 selects between the following time scales: Local, Standard, GPS, UTC, and TAI.

Command Line

To display the current settings, enter:

F90<CR>

XLi responds using the following format:

F90<S><CODE OUTPUT><TYPE><CR>

where:

F

=

ASCII character F.

90

=

function number.

<S>

=

Space

<CODE OUTPUT>

= IRIG-A, IRIG-B, NASA 36

<TYPE>

=

AM, DC

<CR>

=

carriage return character.

<LF>

=

line feed character.

For example, enter:

F90<CR>

XLi responds (example):

F90 IRIG-B AM<CR><LF>

To change the Code Output selection enter:

F90 IRIG-B DC<CR>

XLi responds:

OK<CR><LF>

XLi IEEE 1588 Clock

79

997-01510-03, Rev. C, 12/12/2006

Page 87
Image 87
Symmetricom XLi IEEE 1588 manual To change the Code Output selection enter, F90CR, F90SCODE Outputtypecr, F90 IRIG-B Amcrlf