SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS

::= { systemFaultConfigData 2 }

configDataTimeout OBJECT-TYPE SYNTAX Unsigned32 (0..86400) MAX-ACCESS read-write STATUS current

DESCRIPTION

"The timeout delay, in seconds, after which a time error fault becomes a timeout fault."

::= { systemFaultConfigData 3 }

configDataPowerOnSuppress OBJECT-TYPE SYNTAX Unsigned32 (0..86400) MAX-ACCESS read-write

STATUS current

DESCRIPTION

"The minor alarm power on timeout in seconds." ::= { systemFaultConfigData 4 }

maskPllSynthesizer OBJECT-TYPE SYNTAX FaultMaskType MAX-ACCESS read-write STATUS current

DESCRIPTION

"If enabled, an alarm can be triggered when the PLL synthesizer status changes."

::= { systemFaultConfigMasks 1 }

maskLpnPll OBJECT-TYPE SYNTAX FaultMaskType MAX-ACCESS read-write STATUS current

DESCRIPTION

"If enabled, an alarm can be triggered when the LPN PLL status changes."

::= { systemFaultConfigMasks 2 }

maskPrimaryRefClk OBJECT-TYPE SYNTAX FaultMaskType MAX-ACCESS read-write STATUS current

DESCRIPTION

"If enabled, an alarm can be triggered when the primary reference clock lock status changes."

::= { systemFaultConfigMasks 3 }

maskSecondaryRefClk OBJECT-TYPE SYNTAX FaultMaskType MAX-ACCESS read-write STATUS current

DESCRIPTION

"If enabled, an alarm can be triggered when the secondary reference clock lock status changes."

::= { systemFaultConfigMasks 4 }

168