where:

F= ASCII character F

100= unit function number <S> = space

P= specify Password command <CR> = input line terminator

The XLi responds:

ENTER NEW USER PASSWORD:

When you enter the new password, the XLi responds:

CONFIRM NEW USER PASSWORD:

Enter the same new password again, to confirm the spelling. If the same new password has been entered twice, The XLi responds:

OK<CR><LF>

In this case, the new password will be used for the next login. However, if the new password is entered differently the second time, The XLi responds:

ERROR: PASSWORDS DO NOT MATCH. NEW PASSWORD REJECTED.

F100 PI – PING

Use function F100 PI to ping a remote host to see if it is reachable. If no IP Address is provided, F100 PI uses the XLi’s own IP Address, and tests whether the XLi’s network port has a good network connection.

To ping a known host, enter:

F100 PI<S><IP Address><CR>

For example:

F100 PI 206.254.000.021<CR>

The unit responds (example):

PING 206.254.000.021: REMOTE HOST FOUND.<CR><LF>

or

PING 206.254.000.021 : REMOTE HOST NOT FOUND.<CR><LF>

96

XLi IEEE 1588 Clock

997-01510-03, Rev. C, 12/12/2006

Page 104
Image 104
Symmetricom XLi IEEE 1588 manual F100 PI Ping, When you enter the new password, the XLi responds, Unit responds example