XLi IEEE 1588 Clock 19
997-01510-03, Rev. C, 12/12/2006
2
5
1
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
Configuring Network Settings
The following steps are required to make the XLi’s Main CPU card operational on a network. Do this if
you plan on using the command line or web interface to manage the XLi over the network.
Using the front panel keypad/display configure the network port settings as follows:
Configuring the XLi
Enter the XLi’s IP address as the address in a browser and log on to the XLi’s web interface. The factory
set user name is “operator1” and the password is “zeus”. If this XLi was field-upgraded for IEEE 1588
operation, the password may also be “casey”.
Click the Admin Home link and then the Accounts Admin link. Change the factory set user
names and passwords.
Click the Admin Home link and then the Option Bay # GPS M12 RECEIVER link.
- Verify that the Antenna Cable Delay is correct. For the standard 50 foot (15.24 m) coaxial
cable supplied with the GPS antenna, the Antenna Cable Delay is 60 ns. To compute the cor-
rect value for other antenna cable lengths, see F51 – GPS Antenna Cable Delay” on
page 55.
- Leave GPS Operation Mode as “Dynamic” and Time Reference as “Primary”.
Click the GPS Config & Status link. After approximately 20 minutes of operation, check that
GPS Clock Status is locked and GPS Antenna is OK.
- If GPS Antenna is OK and GPS Clock Status is unlocked, click the GPS Satellite List link.
The Tracked Satellite List should list four or more “current” GPS satellites. It may take signifi-
cantly longer than 20 minutes for four or more “current” GPS satellites to appear if the GPS
Press Result
ENTER Displays “FUNCTION
100 Enters 100 as the function number
ENTER Displays Function 100’s first screen: “COMPANY 00-A0-69…
ENTER Displays “IP ADDRESS…
1-9… Enter the unit’s IP Address (e.g., 192.168.0.11
ENTER Displays “SUBNET MASK…
1-9… Enter the Subnet Mask (e.g., 255.255.255.000)
ENTER Displays “DEFAULT GATEWAY…
1-9… Enter the Default Gateway’s IP address (e.g., 192.168.0.1)
ENTER Displays “10-100 BASE-T (CURR BW 10) - AUTO
ENTER Displays “REMOTE LOCKOUT – UNLOCK” (Leave unchanged)
ENTER (5 times) Displays “SAVE CHANGES – YES
ENTER Saves the new network parameters, and reboots the XLi