Symmetricom XLi IEEE 1588 manual F73 Alarm Control / Status, F72CR

Models: XLi IEEE 1588

1 216
Download 216 pages 35.7 Kb
Page 77
Image 77

SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS

F72<CR>

The XLi responds:

F72<SP>PLL: <CLK PLL ><SP> CLK: <CLK STATUS><SP><CLK REF:><SP> PWR1:<PWR1 STATUS><SP>

PWR2: <PWR2 STATUS><SP>OSC: <OSC STATUS> <CR><LF>

where:

F

=

ASCII character F

72

=

function number

<SP>

= ASCII space character one or more.

<CLK PLL>

= Clock Phase Loop Lock status, LOCKED or UNLOCKED

<CLK STATUS>

=

Clock Status, LOCKED or UNLOCKED to the reference source shown. The

 

 

LOCKED state is based on the F73 Time Threshold value entered by the

 

 

operator. F73 Time Threshold sets the threshold in ns above which Time Error

 

 

triggers an alarm. When the oscillator's predicted worst-case time error ("F13 -

 

 

Time Error" on page 51) exceeds F73 Time Threshold, Time Error enters a fault

 

 

state and the CLOCK STATUS becomes UNLOCKED. Otherwise the CLOCK

 

 

STATUS is LOCKED.

<CLK REF>

=

Clock reference source GPS PRI, GPS SEC, PTP PRI, PTP SEC, (not

 

 

supported: IRIG A, IRIG B, NASA 36) AUX REF.

<PWR1 STATUS>

= Primary Power Supply status, OK or FAILED

<PWR2 STATUS>

=

Secondary Power Supply status, OK or FAILED

<OSC STATUS>

= Rubidium oscillator status, OK or FAILED (if installed)

<CR><LF>

=

output line terminator

For example, enter:

F72<CR>

The XLi responds:

F72 CLOCK PLL

LOCKED

CLOCK STATUS LOCKED GPS PRI

PRIMARY POWER SUPPLY

OK

SECONDARY POWER SUPPLY

OK

F73 – Alarm Control / Status

Use function F73 to do the following:

See the state of an indicator (“Locked/Unlocked” or “OK/Fault”)

Enable or disable the alarm for each indicator

XLi IEEE 1588 Clock

69

997-01510-03, Rev. C, 12/12/2006

Page 77
Image 77
Symmetricom XLi IEEE 1588 manual F73 Alarm Control / Status, F72CR