SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS

Command Line

To display the current settings, enter:

F74<CR>

XLi responds, using the following format:

F74<S><CLK SOURCE><CR><LF>

where:

F

= ASCII character F.

74= function number.

<S>

=

Space

 

<CLK SOURCE> =

Clock Source:

 

 

PRI

 

 

SEC

 

 

PRI-SEC-SEC

 

 

PRI-SEC-PRI

 

 

PRI-NSEC-PRI

<CR>

=

carriage return character.

<LF>

=

line feed character.

For example, enter:

F74<CR>

XLi responds (example):

F74 PRI<CR><LF>

To select PRI-SEC-SEC as the new clock source/fail-over pattern, enter:

F74 PRI-SEC-SEC<CR>

XLi responds:

OK<CR><LF >

F90 – Code Output Configuration

Use function F90 to configure the time code output format (IRIG-A, IRIG-B, or NASA 36) and modulation type (AM or DC) on the XLi’s standard CODE output.