The following reference table identifies the indicators that correspond to each position in F73 mask syntax. Use this table when entering or reviewing MASK settings. Table also provides the factory settings for a unit with one or two GPS receivers:

 

 

 

One GPS receiver

Two GPS receivers

1

=

PLL Synthesizer Alarm Enabled

E

E

2

=

LPN PLL Alarm Enabled

E

E

3

=

GPS Primary Alarm Enabled

E

E

4

=

GPS Secondary Alarm Enabled

D

E

5

=

IRIG Alarm Enabled

D

D

6

=

Aux Ref Alarm Enabled

D

D

7

=

Primary Power Alarm Enabled

E

E

8

=

Secondary Power Alarm Enabled

D

D

9

=

Rb Oscillator Alarm Enabled

E

E

A =

DAC Alarm Enabled

D

D

B =

First time lock Alarm Enabled

E

E

C =

Time error Alarm Enabled

E

E

D =

Time out Alarm Enabled

E

E

E =

NTP Alarm Enabled (if NTP present)

D

D

Note: Alarm Mask does not provide an setting for LED BLINK, which is not an alarm setting. Also, the Rb Oscillator Alarm Enabled setting is available even if a Rubidium oscillator is not present.

To change the Alarm Enabled setting for each indicator, enter to E (Enable), D (Disable), or “-” (Unchanged) using this format:

F73<S>MASK<SEP><123456789ABCDE><CR>

For example, to enter new mask settings, enter:

F73 MASK DDE-EEEEEEEEEE

XLi replies:

OK

To verify the changes, enter:

F73 MASK

XLi replies:

F73 MASK DDE-EEEEEEEEEE

XLi IEEE 1588 Clock