SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS

F131 - Precision Time Protocol Network Config

Note: The IEEE 1588 card becomes available in the user interface after the XLi IEEE 1588 Clock has been operating for approximately 3 to 5 minutes.

Use F131 to view the status of and configure the following items on the IEEE 1588 card:

Option bay location of the IEEE 1588 card (status only)

Static IP address, subnet mask and default gateway for the network port

DHCP enabled/disabled

DHCP-assigned IP address, subnet mask and default gateway for the network port (status only)1

PTP synchronization message interval

PTP burst mode enabled/disabled

PTP network port enabled/disabled

PTP subdomain name

Re-initialize the IEEE 1588 card, restore factory defaults

Re-initialize the IEEE 1588 card, restore the current settings

PTP Master or Slave. If slave, set as primary, secondary, or standby reference source

PTP Slave Synchronization Threshold

PTP Preferred Master Configuration

Option bay location of the IEEE 1588 cards

The option bay number identifies the physical location of the option card in the chassis. The factory configured location of the IEEE 1588 cards are option bay 4 (PTP master) and, when present for TBD option bay 2 (PTP slave). For units that have the second IEEE 1588 card (PTP slave), the card is located in option bay 2. See Figure 7.

Figure 7: Option bay locations (as seen when looking from the side indicated)

Static IP address, subnet mask and default gateway for the network port

The static IP address, subnet mask and default gateway identify the 1588 port on the network.

1. Only displayed when PTP DHCP is set to ENABLE.

XLi IEEE 1588 Clock

119

997-01510-03, Rev. C, 12/12/2006

Page 127
Image 127
Symmetricom XLi IEEE 1588 manual F131 Precision Time Protocol Network Config, Option bay location of the Ieee 1588 cards