Symmetricom XLi IEEE 1588 manual F8 Continuous Time Once-per-Second

Models: XLi IEEE 1588

1 216
Download 216 pages 35.7 Kb
Page 54
Image 54

SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS

XLi responds:

F6<S><STATE><CR><LF>

where:

F= ASCII character F

6 = function number

<S>

= ASCII space character (one or more)

<STATE>

=

ENABLE or DISABLE

<CR>

=

carriage return character

<LF>

=

line feed character

For example, to display the Keypad Lock status, send:

F6<CR>

XLi responds:

F6 DISABLE<CR><LF>

To enable Keypad Lock, send the following string:

F6 ENABLE<CR>

XLi responds:

OK<CR><LF>

To disable Keypad Lock, send the following string:

F6 DISABLE<CR>

XLi responds:

OK<CR><LF>

F8 - Continuous Time Once-per-Second

The function F8 commands and outputs are available only on the command line interface (through the serial and network ports). They are not available through the keypad display or web interfaces.

Function F8 outputs the time-of-year once per second, conditionally followed by a time quality character.

F8 is affected by the following functions:

F2 – 12/24 Hour Format (page 39)

46

XLi IEEE 1588 Clock

997-01510-03, Rev. C, 12/12/2006

Page 54
Image 54
Symmetricom XLi IEEE 1588 manual F8 Continuous Time Once-per-Second, For example, to display the Keypad Lock status, send