Triggered Recording

Triggered Recording Settings

The Settings section of the Triggered Recordings dialog is used to set up the trigger event, including the pre-trigger properties and the amount of memory to be reserved for the recording.

Trigger Type The event that triggers the recording can be one of four types, selected from the drop-down list.

Immediate

The trigger is set as soon as Arm Trigger is selected on the

Operations section; in effect, recording will start immediately.

External Rising Edge / External Falling Edge

The trigger is set when Arm Trigger has been selected on the Operations section. Recording will start when a rising / falling edge is detected at the TTL input on the TS Processor, Alarms connector (see the MTM400 Technical Reference for specifications).

Event Alarm

The trigger is set when Arm Trigger has been selected on the Operations section. Recording will start when an error occurs on an event that has been flagged in the Tests or Custom views.

3-100

MTM400 MPEG Transport Stream Monitor User Manual