Stream View
Test Selection
The Test:
The following PID tests can be selected from the Test:
| Any PID Error | PCR Drift Rate ** | |
PID Bit Rate * | | PTS Repetition | |
| PCR Repetition | | PID Variability * |
| PCR Discontinuity | | Missing PID |
| PCR Accuracy | | Unreferenced PID |
PCR Overall Jitter ** | | Continuity | |
| PCR Frequency Offset** | | Discontinuity |
*Require Bit Rate Testing to be licensed (License Option 05, Table
**Require PCR Testing to be licensed (see Table
The results of the tests are indicated by the Test icons. Where the test is inapplicable, the icon will be white.
For most of the tests, the parameters applied to each PID can be varied by right- clicking on the Test state button and selecting the Parameters… option.
Each of these tests and the associated parameters are described in the MTM400 MPEG Transport Stream Monitor Programmer Manual.
The results of tests applied here are not reflected in the PID Groups.
MTM400 MPEG Transport Stream Monitor User Manual |