Getting Started
Electrical Installation
The electrical operating requirements of the MTM400 are summarized in
Table
Reference for more detailed electrical characteristics.
Table
Requirement | Specification |
Temperature, operating | +5 ˚C to +40 ˚C |
Altitude, operating | 0 m to 3000 m (9800 ft) |
Source Voltage | 100 VAC to 240 VAC, 50 Hz/60 Hz |
Power Consumption (maximum) | 1 Amp |
Peak Inrush Current | 7.2 A peak at 240 VAC, 50 Hz |
Fuse Rating | Mains fuse is 3.15 A, 250 V, Fast; Not operator |
| replaceable. Refer servicing to qualified service |
| personnel. |
Overvoltage Category | II (as defined in |
Pollution Degree | 2 (as defined in |
| Rated for indoor use only. |
Use the following procedure to make electrical, signal, and network connections:
1.After the MTM400 has been mounted in the rack, connect the power cord (provided with the unit) to the power connector on the rear panel. Connect the power cord plug to a properly grounded outlet.
Power |
| Transport Stream |
| Interface Card |
| ||
| Processor Card |
| (where installed) |
| |||
|
|
|
| Additional |
|
|
|
|
|
|
| information |
|
|
|
|
|
|
| found on label |
|
|
|
|
|
| ASI/ | on top panel |
|
|
|
| IN | QPSK | IN | OUT |
| ||
| LAN | LTC | SMPTE OUT | ALARMS |
| IN | LNB |
| 1 |
|
| LOCK | POWER | ||
|
|
|
|
| |||
| Serial No. |
|
| 2 |
|
|
|
|
|
|
| 6 |
|
|
|
Tektronix Inc. Beaverton OR. |
|
|
|
|
|
| |
1A MAX | U.S.A. |
|
|
|
|
|
|
| Ethernet | TS Input | Alarms |
|
|
| |
| LTC In | TS Output |
|
|
|
Figure
2.Make the necessary transport stream, network and peripheral device connections using the connectors at the rear of the unit.
MTM400 MPEG Transport Stream Monitor User Manual |