Getting Started

Electrical Installation

The electrical operating requirements of the MTM400 are summarized in

Table 1-6; see the MTM400 MPEG Transport Stream Monitor Technical

Reference for more detailed electrical characteristics.

Table 1-6: Electrical operating requirements

Requirement

Specification

Temperature, operating

+5 ˚C to +40 ˚C

Altitude, operating

0 m to 3000 m (9800 ft)

Source Voltage

100 VAC to 240 VAC, 50 Hz/60 Hz

Power Consumption (maximum)

1 Amp

Peak Inrush Current

7.2 A peak at 240 VAC, 50 Hz

Fuse Rating

Mains fuse is 3.15 A, 250 V, Fast; Not operator

 

replaceable. Refer servicing to qualified service

 

personnel.

Overvoltage Category

II (as defined in IEC61010-1)

Pollution Degree

2 (as defined in IEC61010-1).

 

Rated for indoor use only.

Use the following procedure to make electrical, signal, and network connections:

1.After the MTM400 has been mounted in the rack, connect the power cord (provided with the unit) to the power connector on the rear panel. Connect the power cord plug to a properly grounded outlet.

Power

 

Transport Stream

 

Interface Card

 

 

Processor Card

 

(where installed)

 

 

 

 

 

Additional

 

 

 

 

 

 

 

information

 

 

 

 

 

 

 

found on label

 

 

 

 

 

 

ASI/

on top panel

 

 

 

 

00-01-F8-A7-33-CC

IN

QPSK (L-BAND)

IN

OUT

 

 

LAN

LTC

SMPTE OUT

ALARMS

 

IN

LNB

 

1

 

 

LOCK

POWER

 

 

 

 

 

 

Serial No.

 

 

2

 

 

 

 

 

 

 

6

 

 

 

100-240 VAC 50/60 Hz

Tektronix Inc. Beaverton OR.

 

 

 

 

 

 

1A MAX

U.S.A.

 

 

 

 

 

 

 

Ethernet

TS Input

Alarms

 

 

 

 

LTC In

TS Output

 

 

 

Figure 1-1: MTM400 connectors (shown with QPSK interface)

2.Make the necessary transport stream, network and peripheral device connections using the connectors at the rear of the unit.

MTM400 MPEG Transport Stream Monitor User Manual

1-9