Interface Configuration and Interpretation

QAM (Annex B II)

The QAM (Annex B II) Settings dialog box is shown in Figure 3-42.

Configuration - QAM (Annex B II)

Figure 3-42: Interface configuration – QAM Annex B II

For each of the settings, enter the required change and select Set to apply the new value. The settings are as follows:

NOTE. These settings can also be made from the Input Card screen.

Configurations: The QAM Settings dialog provides an option to recall a number of settings configuration files. The configuration files are created and stored in the MTM400. To select a configuration file, highlight the required name in the list.

Tuner Frequency (kHz):

This value, set in kHz units, is the center frequency of the channel to be received. Any frequency can be entered. There is no need to follow a channel plan. The frequency resolution is determined by the tuner step size of 62.5 kHz.

3-118

MTM400 MPEG Transport Stream Monitor User Manual