Appendix A: Network Installation

If necessary, obtain the Gateway and Subnet Mask values from the Network Administrator.

4.When the settings have been changed and set and Close is selected, the following dialog is displayed:

Select OK to restart the device and for the settings to take effect. Select Cancel if a restart is not required (the settings will take effect the next time that the unit is restarted).

The unit will be restarted, but the current network will not be able to communicate with it. At this point the unit must be disconnected and moved to its new location. If the new IP address was correctly entered, it should be immediately available on the new network. However, if the new network is unable to communicate with the new unit, you may need to reset the unit and reenter the new IP address, as described below.

Resetting the IP Address to Factory Default

An existing IP address can be reset to the factory default ('0.0.0.0') by resetting the battery-backed non-volatile RAM on the Transport Stream Processor board. Clearing the RAM resets all configuration data, including the IP address, to the factory defaults.

NOTE. Another consequence of clearing the non-volatile RAM is the loss of the licensing information; the license key must be reentered after setting the IP address.

MTM400 MPEG Transport Stream Monitor User Manual