Stream View
Select the Close button to retain the temporary settings and close the dialog.
Information Screen
The Information screen displays stream events and messages.
Stream events and messages may be logged but do not constitute a test failure; for example, a version change of a table carried in the SI/PSI is reported in the stream log but is not subject to a standard test. The only place that these stream events are recorded is in the stream logs. This screen collects these all in one place and allows their recording in the stream log to be enabled or disabled. Alarms can be raised when a message occurs.
The messages to be displayed are set at the factory; interface cards can also generate messages.
Figure
The layout and functionality is similar to the Tests screen; a single column of icons is added, that is Log.
LogOff - ; On -
;
Enables/disables message recording in the stream log.