Stream View
Figure
The PCR Arrival graph provides a display of the time interval between successive PCRs, during the last 256 PCRs. The interval is displayed on the
The PCR Maximum Repetition Interval can be adjusted for individual PIDs as follows:
PIDs screen Î Test: select PCR Repetition Î individual PID parameter
PCR Overall Jitter (PCR_OJ)
The PCR Overall Jitter graph shows the difference between the actual value of the PCR (expressed as a time) and its expected value based on its measured arrival time.
MTM400 MPEG Transport Stream Monitor User Manual |