BTU Output for Standard STAR® Burners

BTU Output for Standard STAR® Burners

HI is equivalent to 18,000 BTU / HR (15,000 BTU / HR using Propane).

SIM is equivalent to 2,100 BTU / HR.

BTU Output for ExtraLow® STAR® Burners

HI is equivalent to 18,000 BTU / HR (15,000 BTU / HR using Propane).

SIM is equivalent to 3,000 BTU / HR.

XLO® is equivalent to 375 BTU / HR when the control knob is adjusted to the lowest setting in the ExtraLow range.

ExtraLow® STAR® Burners

The controls for the two left burners, front and rear, have flame settings even lower than the standard SIM settings.

Figure 5 shows that the control knob has an additional range between the SIM and XLO settings. When the knob is set within this range, the flame cycles off and on. By varying the length of time the flame is off and on, the heat is reduced even further to cook delicate foods. For example, these very low settings are suitable for simmering and poaching, melting chocolate and butter, holding cooked foods at temperatures without scorching or burning, etc.

ExtraLow® Techniques

The type and quantity of food affects which setting to use.

The pan selected affects the setting. Its size, type, material, and whether a lid is used, all affect the consistency of the cooking temperature.

To maintain a low or simmer heat, bring food to a rolling boil. Stir well, then cover the pan and lower the heat to a setting just below SIM.

Check periodically to see if the control knob should be turned to another setting.

If an over-size pan is used, the simmer action may occur mainly in the center of the pan. To equalize the temperature throughout the food, stir the food around the outer edges of the pan into the food in the center.

It is normal to stir food occasionally while simmering. This is especially important when simmering for several hours, such as for a homemade spaghetti sauce or beans.

When lowering the flame setting, adjust it in small steps.

If the setting is too low to hold a simmer, bring the food back to a boil before re-setting to a higher heat.

It is normal not to see simmer bubbles immediately after the food has been stirred.

There may be bubbling when the flame cycles on and no bubbles when the flame is off. Even when the flame is off, there will be steam and a slight quiver on the liquid’s surface.

ExtraLow

Range

BTU Output for ExtraLow® STAR® Burners OFF ExtraLow® STAR® BurnersExtraLow® TechniquesOperation of the ExtraLow® BurnerManual backgroundManual backgroundManual backgroundManual backgroundXLO Manual backgroundManual backgroundManual backgroundManual background

Manual backgroundManual backgroundManual backgroundManual backgroundXLO

OFF

IMPORTANT:

For proper combustion, DO NOT use the rangetop without the burner grates in place.

There is a slight sound associated with gas combustion and ignition. This is normal.

On rangetops using propane (LP) gas, a slight “pop” sound may be heard from the STAR burner ports a few seconds after the burner has been turned off.

Manual backgroundWARNING:

Figure 5: ExtraLow STAR Burner Control Knob

Operation of the ExtraLow® Burner

XLO, the very lowest setting, is achieved by cycling the flame on for approximately 7 seconds and off for 53 seconds of each minute.

When the knob is rotated just beyond the SIM setting, the flame will cycle on for approximately 54 seconds and off for 6 seconds of each minute.

To vary the amount of low heat, the control can be set anywhere within the SIM and XLO range marked on the knob.

This product contains or, through ordinary use for its intended purpose, facilitates emission of chemicals or other substances known to the State of California to cause cancer and/or birth defects or other reproductive harm. To minimize exposure to these chemicals:

1)The burners should be adjusted by a certified installer or agency to ensure proper combustion.

2)Ensure proper ventilation with an open window or use a ventilation fan or hood when cooking with gas.

3)ALWAYS operate the unit according to the instructions in this manual.