Electrical Requirements

IMPORTANT SAFETY INSTRUCTIONS

Read and Save These Instructions

Electrical Requirements

Safety Codes and StandardsWARNING:

IN CASE OF AN ELECTRICAL FAILURE

If for any reason a gas control knob is turned ON and there is no electrical power to operate the electronic igniters on the rangetop STAR® burners, turn OFF the gas control knob and wait 5 minutes for the gas to dissipate before lighting the STAR burner manually.

To light the STAR burners manually, carefully hold a lighted match to the STAR burner ports and turn the gas control knob to HI. During a power failure, you can use the standard rangetop STAR burners, but each must be lit with a match.

DO NOT attempt to light the two left XLO® STAR burners manually. These STAR burners are equipped with the ExtraLow® feature and cannot be lit manually.

It is the personal responsibility and obligation of you, the user, to have this appliance connected to the electrical power supply by a qualified electrician, in accordance with the National Electrical Code and/or applicable local codes and ordinances.

All rangetop models require an electrical circuit rated at 120 volts, 60 Hz., 10 Amps, except models with electric griddle require 15 Amp circuits.

Manual backgroundCAUTION:

FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE CONNECTED TO A PROPERLY GROUNDED AND POLARIZED ELECTRICAL POWER SUPPLY.

Always disconnect the electrical plug from the wall receptacle before servicing this unit.

See the Installation Manual for electrical requirements and grounding instructions.

Safety Codes and Standards

This appliance complies with the following Standards:

UL 858, The Standard for the Safety of Household Electric Ranges

ANSI Z21.1, The American National Standard for Household Cooking Gas Appliances

CAN 1-1.1-M81, Domestic Gas Ranges

CSA C22.2 No. 61, Household Cooking Ranges

Check your local building codes for the proper method of installation. In the absence of local codes, this unit should be installed in accordance with the National Fuel Gas Code No. Z223.1 current issue and the National Electrical Code ANSI/NFPA No. 70 current issue or the Can - B149 Installation Codes for Gas Burning Appliances and C22.1 Canadian Electrical Code Part 1.

It is the responsibility of the owner and the installer to determine if additional requirements and/or standards apply to specific installations.

When properly cared for, your new THERMADOR PROFESSIONAL® rangetop has been designed to be a safe, reliable appliance. However, use extreme care when using this restaurant caliber rangetop as this type of appliance provides intense heat. When using kitchen appliances, basic safety precautions must be followed, including the following:

Read this Use and Care Guide carefully before using your new rangetop to reduce the risk of fire, electrical shock, or injury to persons.

Insure proper installation and servicing. Follow the Installation Manual provided with this product. Have the rangetop installed and electrically grounded by a qualified technician.

Have the installer show you where the electric circuit breaker and the gas supply shut off valve are located so you know how and where to turn off the gas and electricity to the rangetop.

In the event a STAR® burner goes out and gas escapes, open a window or a door. DO NOT attempt to use the rangetop until the gas has had time to dissipate. Wait at least 5 minutes before using the rangetop.

DO NOT repair or replace any part of the appliance unless specifically recommended in this manual. All servicing should be referred to a qualified technician.

English 2