Toshiba B-EX4T1 manual Parameter Setting Cont, 16 XML, Threshold Select, Energy Type, Pw Save Time

Models: B-EX4T1

1 124
Download 124 pages 887 b
Page 36
Image 36
(16) XML

2. PRINTER SETUP

ENGLISH VERSION EO1-33089

2.6 Printer Setting

2.6.2Parameter Setting (Cont.)

(16) XML

This parameter is to choose a type of XML data to be printed.

OFF

Disables XML data printing.

STD

Standard specification

ORACLE

Oracle

SAP

SAP

STD EXT

Standard specification (External memory)

ORACLE EXT Oracle using an external memory

• SAP EXT

SAP using an external memory

(17) THRESHOLD SELECT

This parameter is to choose which threshold value for the media sensor to validate.

REFLECT

Reflective sensor

TRANS.

Transmissive sensor

Then, choose which value to use.

 

• MANUAL SET

Threshold set in the Threshold mode takes

 

 

 

effect.

 

• COMMAND SET

Threshold set by command takes effect.

(18) ENERGY TYPE

This parameter is to choose an energy level applied to the print head.

TRANSFER

Thermal transfer print method → c

DIRECT

Thermal direct print method → d

cWhen TRANSFER is selected for the Energy type parameter,

choose a ribbon type.

 

• Semi resin1

Semi-resin 1

• Semi resin2

Semi-resin 2

• Resin1

Resin 1

• Resin2

Resin 2

• Reserve1 to Reserve6

Reserved

dWhen DIRECT is selected for the Energy type parameter

• Standard

Standard

• Reserve1 to Reserve9

Reserved

(19) PW SAVE TIME

This parameter is to set the length of time until the printer enters the sleep mode. (Unit: minute)

240min.

239min.

2min.

1min.

E2-22