2. PRINTER SETUP
ENGLISH VERSION
2.6 Printer Setting
2.6.6 Automatic Calibration
USER SYSTEM MODE
<4>LAN/WLAN
<5>BASIC
<7>AUTO CALIB
The Auto Calibration menu allows selecting whether or not to enable the automatic calibration at a power on time. When the automatic calibration is activate, the printer feeds the media for about 160 mm each time the power is turned on or the top cover is opened, to detect a print start position.
(1) AUTO CALIB |
| |
• | OFF | Disabled. |
• | ON TRANS. | Enabled. (Transmissive sensor) |
• | ON REFLECT | Enabled. (Reflective sensor) |
• | ON ALL | Enabled. (Transmissive & Reflective |
|
| sensors) |
• | ON TRANS.+Bfeed | Auto calibration + back feed |
|
| (Transmissive sensor) |
• | ON REFLECT+Bfeed | Auto calibration + back feed |
|
| (Reflective sensor) |
• | ON ALL+Bfeed | Auto calibration + back feed |
|
| (Transmissive & Reflective sensors) |
NOTES:
1.When AUTO CALIB is enabled, an automatic calibration is performed at an open/close of the print head and at a power on time.
2.When AUTO CALIB is enabled, the media length, effective print length, sensor type, and whether to use ribbon or not specified by commands are ignored.
3.This function is available only when the media pitch is 10.0 mm to 150.0 mm.
4.When the printer cannot detect the second black mark/gap, it will continue to feed the media for up to 500.0mm. If this does not work, the printer will stop, resulting in a paper jam.
5.During an automatic calibration, the printer also feeds the ribbon. Even if the ribbon is not loaded, no error results. However, the print condition will be automatically changed to “No ribbon” after the calibration ends.
6.When the cutter is installed and a previous issue was performed in cut issue mode, the media is cut and ejected after an automatic calibration completes.
7.When a label end or a head open occurs during an automatic calibration, the printer stops, resulting in an error. Loading new media and closing the print head can clear the error and resume the automatic calibration.
8.The media is fed backward after an auto calibration is performed if the reverse feed is enabled.