2.9.1 Fine Adjustment (Cont.)

2. PRINTER SETUP

ENGLISH VERSION EO1-33089

2.9 Position and Print Tone Fine Adjustment

2.9.1 Fine Adjustment (Cont.)

(8) RBN ADJ.<BK>

When the ribbon is slack or wrinkled and printing is affected, fine adjust the ribbon motor torque.

NOTE:

When “0.0 V” is se for this parameter, it is automatically corrected to 1.0V (default) after the power is turned OFF then ON.

+10

High

+9

Motor torque

-14

-15 Low

(9) THRESHOLD <REFL.>

When you perform a threshold setting for the reflective sensor and found the threshold needs to be adjusted, set a fine adjustment value.

This menu is accessible directly from the Threshold Setting Mode so that the threshold can be manually set right away.

Manually set threshold = Peak voltage – The value set here

For details, refer to Section 2.10.

4.0V

3.9V

0.1V

0.0V

NOTE:

When “0.0 V” is se for this parameter, it is automatically corrected to 1.4V (default) after the power is turned OFF then ON.

(10) THRESHOLD <TRANS.>

When you perform a threshold setting for the Transmissive sensor and found the threshold needs to be adjusted, set a fine adjustment value. This menu is accessible directly from the Threshold Setting Mode so that the threshold can be manually set right away. .

Manually set threshold = Peak voltage – The value set here

For details, refer to Section 2.10.

4.0V

3.9V

0.1V

0.0V

E2-66