2.10Threshold Setting (Cont.)

2.PRINTER SETUP

ENGLISH VERSION EO1-33089

2.10 Threshold Setting

2.10Threshold Setting (Cont.)

NOTE:

To make a threshold value set in this section effective, select the Transmissive Sensor (when using pre-printed media) or Reflective Sensor (when using manual threshold value) in Issue Command or the printer driver.

 

Display example

Explanation

1

 

Result: OK (Mid.)

 

 

Threshold is at the midpoint between the

 

 

peak and the baseline.

2

 

Result: OK (High)

 

 

Threshold is near the peak voltage.

 

 

Adjusting the threshold to the midpoint

 

 

between the peak and the baseline enables

 

 

more accurate detection.

3

 

Result: OK (Low)

 

 

Threshold is near the baseline voltage.

 

 

Adjusting the threshold to the midpoint

 

 

between the peak and the baseline enables

 

 

more accurate detection.

4

 

Failed (1)

 

 

The media sensor cannot detect a gap/black

 

 

mark. Sensor adjustment is required.

 

 

(⇒Section 2.11)

5

 

Failed (1)

 

 

The media sensor cannot detect a gap/black

 

 

mark. (Threshold ≤ Baseline) Sensor

 

 

adjustment is required. (⇒Section 2.11)

6

 

Failed (2)

 

 

Detection by the media sensor is disabled.

 

 

Sensor adjustment is required. (⇒Section

 

 

2.11)

(5) Press the [RIGHT] to see the details.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(e.g: Succeeded)

 

(e.g.: Failed)

 

Sensor type Peak voltage Threshold voltage Baseline voltage Key operation guide

NOTE:

The threshold can be manually set as follows:

Manually set threshold = Peak voltage – Threshold fine adjustment value

e.g.) When Peak=3.5V and Fine adjustment value=1.0V, the threshold will be set to 2.5V.

(6)To return to the previous display, press the [LEFT].

To adjust the threshold, press the [RIGHT]. The threshold fine adjustment screen in ADJUST SET menu appears.

Set a value and press the [ENTER].

(7)The result after manually setting the threshold is displayed.

E2-68

Page 82
Image 82
Toshiba B-EX4T1 manual Threshold Setting Cont, Press the RIGHT to see the details, e.g Succeeded, e.g. Failed