2.PRINTER SETUP
ENGLISH VERSION
2.11 Threshold Setting
2.11Threshold Setting (Cont.)
<5>SENSOR ADJ. [REFLECT] 3.5V
<5>SENSOR ADJ. [REFLECT] 4.8V*
<5>SENSOR ADJ. [TRANS.] 2.4V
Voltage at a label gap
Midpoint (Threshold voltage)
Voltage at a print area
(3)Press and hold the [RESTART] or [FEED] key for about 3 seconds aligning a blank part of print area with the Black Mark Sensor.
(4)When storing a “media level” voltage is completed, an asterisk “*”is displayed on the right side of a voltage. Press the [PAUSE] key.
(5)A
When using the Feed Gap Sensor
(1)Measure a voltage at a blank part of label and a label gap, respectively. At this time, write down the midpoint of both voltages. (This value is used later for a threshold setting.)
(Example) |
|
Print area = 2.4V, Gap = 4.0V | Midpoint = 3.2V |
NOTES:
1.When measuring a voltage at a blank area, be careful not to align a
2.Confirm that there is at least 0.7V difference between the two values. If the difference in voltage is less than 0.7V, a print start position cannot be detected. In that case, please consider changing the media type.
3.Make sure that the Top Cover is closed when measuring the voltages.
<5>SENSOR ADJ. [TRANS.] 2.4V
<5>SENSOR ADJ. [TRANS.] 2.4V*
<5>SENSOR ADJ. [PE]R0.1V T4.8V
(3)Press and hold the [RESTART] or [FEED] key for about 3 seconds aligning a blank part of print area with the Feed Gap Sensor.
(4)When storing a “media level” voltage is completed, an asterisk “*”is displayed on the right side of a voltage. Press the [PAUSE] key.
(5)The display changes as shown on the left.