2.PRINTER SETUP

ENGLISH VERSION EO1-33048

2.11 Threshold Setting

2.11Threshold Setting (Cont.)

<5>SENSOR ADJ. [REFLECT] 3.5V

<5>SENSOR ADJ. [REFLECT] 4.8V*

<5>SENSOR ADJ. [TRANS.] 2.4V

Voltage at a label gap

Midpoint (Threshold voltage)

Voltage at a print area

(3)Press and hold the [RESTART] or [FEED] key for about 3 seconds aligning a blank part of print area with the Black Mark Sensor.

(4)When storing a “media level” voltage is completed, an asterisk “*”is displayed on the right side of a voltage. Press the [PAUSE] key.

(5)A real-time voltage being detected by the Feed Gap Sensor is displayed.

„When using the Feed Gap Sensor

(1)Measure a voltage at a blank part of label and a label gap, respectively. At this time, write down the midpoint of both voltages. (This value is used later for a threshold setting.)

(Example)

 

Print area = 2.4V, Gap = 4.0V

Midpoint = 3.2V

NOTES:

1.When measuring a voltage at a blank area, be careful not to align a pre-print with the sensor by mistake.

2.Confirm that there is at least 0.7V difference between the two values. If the difference in voltage is less than 0.7V, a print start position cannot be detected. In that case, please consider changing the media type.

3.Make sure that the Top Cover is closed when measuring the voltages.

<5>SENSOR ADJ. [TRANS.] 2.4V

<5>SENSOR ADJ. [TRANS.] 2.4V*

<5>SENSOR ADJ. [PE]R0.1V T4.8V

(3)Press and hold the [RESTART] or [FEED] key for about 3 seconds aligning a blank part of print area with the Feed Gap Sensor.

(4)When storing a “media level” voltage is completed, an asterisk “*”is displayed on the right side of a voltage. Press the [PAUSE] key.

(5)The display changes as shown on the left.

E2-63

Page 76
Image 76
Toshiba B-SA4TP, B-SA4TM-GS12-QM-R, BSA4TMGS12QMR manual „ When using the Feed Gap Sensor