2. PRINTER SETUP

ENGLISH VERSION EO1-33048

2.7 Setting an Operating Environment

2.7.2Parameter Setting (Cont.)

„Serial (RS-232C) Interface

NOTES:

1. When using the hardware flow

(5) Flow Control

This parameter is to choose a flow control of the RS-232C interface.

As “XON+READ AUTO” has been chosen as default, change it in accordance with your PC.

control, the control signals and

data must be in pairs between

the printer and the PC.

Printer

 

Host

TD

RD

RD

-

TD

RTS

CTS

CTS

-

RTS

DSR

DTR

DTR

-

DSR

[RESTART]

[FEED]

<2>PARAMETER SET XON+READY AUTO

XON/XOFF AUTO

XON+READY AUTO

READY/BUSY

XON/XOFF

READY/BUSY RTS

Refer to the RS-232C connector’s pin layout in APPENDIX 2. Check if the printer and the PC is properly connectable with your cable

2.Be careful that there are two types of RS-232C cable; straight cable and cross cable.

Use a straight cable for this printer.

„LCD Message Language

XON/XOFF AUTO: XON/XOFF mode (Software Flow Control)

XON+READY AUTO: XON/XOFF + READY/BUSY (DTR) mode

 

(Software & DTR/DSR Hardware Flow

 

Control)

READY/BUSY:

READY/BUSY (DTR) mode

 

(DTR/DSR Hardware Flow Control)

XON/XOFF:

XON/XOFF mode (Software Flow Control)

READY/BUSY RTS:

RTS mode (CTS/RTS Hardware Flow

 

Control)

After making a choice, press the [PAUSE] key.

This parameter is to choose a language of the LCD Message Display. As “ENGLISH” has been chosen as default, change it as you like.

[RESTART]

[FEED]

<2>PARAMETER SET LCD ENGLISH

ENGLISH

ITALIAN

JAPANESE

SPANISH

DUTCH

FRENCH

GERMAN

After making a choice, press the [PAUSE] key.

E2-21

Page 34
Image 34
Toshiba B-SA4TP, B-SA4TM-GS12-QM-R, BSA4TMGS12QMR manual Flow Control, „ LCD Message Language, Xon/Xoff, Ready/Busy Rts