2. PRINTER SETUP

ENGLISH VERSION EO1-33048

2.7 Setting an Operating Environment

2.7Setting an Operating Environment

ON LINE

[PAUSE]

PAUSE

Hold down [RESTART] for 3 sec.

<1>RESET

[FEED] [RESTART]

<2>PARAMETER SET

[FEED] [RESTART]

<3>ADJUST SET

[FEED] [RESTART]

<4>DUMP MODE

[FEED] [RESTART]

<5>EXPAND MODE

[FEED] [RESTART]

NOTES:

1.System Mode menus can be selected with the [RESTART] or [FEED] key.

2.To enter each of the above System Mode menus, press the [PAUSE] key when the menu is displayed.

Depending on the settings of your host computer or an interface to be used, it may be necessary to change the printer parameter settings.

Follow the procedures described below to change the printer parameter settings in the System Mode to correspond to your environment.

NOTE:

Incorrect settings can cause the printer to function erroneously. If you have any problems with the parameter settings, please contact your nearest TOSHIBA TEC service representative.

For the settings this manual does not cover, please contact your nearest TOSHIBA TEC service representative, or refer to the B-SA4T Series Key Operation Specification stored in the CD-ROM.

The System Mode consists of the following menus.

<1>RESET

This menu is used to clear print data sent from a

 

PC and return the printer to an idle state.

 

Refer to Section 3.3 Reset.

<2>PARAMETER SET

This menu is used to set the printer parameters.

<3>ADJUST SET

This menu is used to make a fine adjustment of a

 

print start position, cut position, etc.

 

Refer to Section 2.10 Position and Print Tone

 

Fine Adjustment.

<4>DUMP MODE

This menu is used to print the data in the receive

 

buffer for debug.

<5>EXPAND MODE

This menu is used to start the program for

 

BASIC mode.

 

Refer to the B-SA4T Series Key Operation

 

Specification stored in the CD-ROM.

E2-16

Page 29
Image 29
Toshiba BSA4TMGS12QMR, B-SA4TM-GS12-QM-R manual Refer to .3 Reset, Fine Adjustment, Refer to the B-SA4T Series Key Operation