5. PROGRAMMING OPERATIONS

EO1-11138

5.4 How to Access a Program Item

Day Part Setting (Submode 46)

A maximum of 6 day parts can be set. You can obtain major group sales data by each day part.

CONDITION

After Day Part Reset

When you enter 46 and depress the [X] key,

 

 

the screen shown below will appear.

OPERATION

Mode Lock: SET

 

* SET *02-06-199912:34

PROGRAMMING DAY PART 01 02 03 04 05 06

Please input data.

0.00

Pg up

 

Pg dw

 

Enter

 

46 [X] Hour Minute [#] [AT/TL]

Enter the time that ends each day part, in the 24- hour system.

Repeat until all the day parts are entered. (max. 6 day parts)

ex.) To set the following day part table. Day Part 1: Up to 10:00*

Day Part 2: 10:01 to 14:00

Day Part 3: 14:01 to 18:00

Day Part 4: 18:01 to 22:00

*(The first day part is automatically continued from 22:01 of the preceding day.)

Mode Lock: SET

Enter 46, depress [X].

1000 [#] 1400 [#] 1800 [#] 2200 [#] [AT/TL]

Journal Print

P46 DAY PART

10:00TM

14:00TM

18:00TM

22:00TM

0083 10:40TM

NOTES: 1. A maximum of 6 day parts can be set.

2.To change the table of day parts once set, partially or entirely, do the entire setting operation over again.

2.To reset the day parts table once set, operate: Mode Lock: SET

46 [X] 0 [#] [AT/TL]

Then no day part sales data will be outputted on the reports.

3.Do not set a day part across 24:00, such as “from 23:00 to 1:00”. If set, no data will be processed into that day part.

5-48

Page 147
Image 147
Toshiba FS-2600-1 owner manual Hour Minute # AT/TL, 1000 # 1400 # 1800 # 2200 # AT/TL, P46 DAY Part