5. PLU MAINTENANCE

EO1-11138

5.2 PLU Price Change with DLL (Submode 73)

Deletion

CONDITION

The sales data of the required PLUs are zero and all terminals are outside a sale,

 

programming, or report taking operations.

OPERATION

Mode Lock: SET and RTR Declaration is ON

63 [X]

 

[ITEM CORR]

 

PLU Code [PLU]

 

 

[AT/TL]

Repeatable for other PLUs to be deleted.

NOTES: 1. When the [AT/TL] key is depressed in the above operation, the master terminal sends each satellite terminal (or the designated satellite terminals) the DLL start command to make it “HOLD” condition. And then, the master terminal sends the DLL data to each terminal. After the DLL is completed, the master terminal sends each terminal the DLL end command to release it from “HOLD” condition. However, a program option allows you to perform a DLL operation even while each terminal is not in idle status.

2.A maximum of 100 PLU tables can be added or changed in one DLL operation sequence.

5.2PLU Price Change with DLL (Submode 73)

This DLL operation is used to change a PLU price on each price level, and send the data to each satellite terminals.

CONDITION

Any time outside a sale for Master or Satellite

OPERATION

Mode Lock: SET and RTR Declaration is ON

Repeatable for other PLUs

73 [X]

PLU Code [PLU]

 

 

 

 

Max. 6 digits

 

 

 

 

 

[PLU Preset-code Key]

 

 

[MENU 1 to 5]

 

 

 

 

Price Level [ST]

New Preset Price

[#]

[AT/TL]

 

1 to 5

Max. 6 digits

 

 

Repeatable for a price change of another price level. When you change the price of each price level in numerical order, the price level designation can be skipped.

NOTES: 1. When the [AT/TL] key is depressed in the above operation, the master terminal sends each satellite terminal (orthedesignatedsatelliteterminals)theDLLstartcommandtomakeit“HOLD”condition.Andthen,themaster terminal sends the DLL data to each terminal. After the DLL is completed, the master terminal sends each terminal the DLL end command to release it from “HOLD” condition. However, a program option allows you to perform a DLL operation even while each terminal is not in idle status.

2.A maximum of 100 PLU prices can be changed in one DLL operation sequence.

3.When zero is entered as the New Preset Price value, the PLU is set with a zero price. When the New Preset Price entry is skipped and the [#] is simply depressed, it will be an open-price PLU.

5-3

Page 198
Image 198
Toshiba FS-2600-1 owner manual PLU Price Change with DLL Submode, Programming, or report taking operations