3. PROGRAMMING OPERATIONS

EO1-11138

3.2 Programming Operations Added for In-line Terminals

Through the Keyboard

 

 

 

69 [X]

 

 

 

In-line ID No. [ST]

 

 

Register No. [#]

 

 

 

 

 

 

 

. . .

 

 

. . .

 

 

 

 

1 to 16

*

 

0 to 999999

 

 

 

(NOTES 1 & 2 below)

 

 

(NOTE 2 below)

 

 

 

 

 

 

 

 

Repeat for other terminals to be connected, including the Master Terminal itself.

[AT/TL]

*For sequentially programming In-line ID Nos., the In-line ID specification can be skipped.

ex.) To set the following.

 

 

Master Terminal

ID No. 1

Register No. 3001

Satellite Terminal

ID No. 3

Register No. 3002

Mode Lock: SET/RTR Declaration is ON.

69[X]

1 [ST] 3001 [#]

3 [ST] 3002 [#]

[AT/TL]

 

Journal Print

 

P69

CONNECT REG

#01

 

#3001

#03

 

#3002

 

0196

01:52TM

NOTES: 1. In-line ID No.: Master Terminal

1 (fixed)

 

Backup Master Terminal (if connected)

2 (fixed)

 

Satellite Terminals

3 to 16 (max. 14 terminals)

However, a number of the connectable terminals differs depending on your system configuration. Refer to the chapter 1. SYSTEM CONFIGURATION of the Operator’s Guide.

2.The In-line ID No. and Register No. of each terminal to be set here must be the same as those programmed for the terminal in In-line Terminal ID Setting (Submode 77) and Store/Register No. Setting (no submode) in Chapter 5 in the Manager’s Guide for stand-alone level.

3.To delete an individual terminal from the Terminal Connection Table, enter 0 in place of the In- line ID No. in the above operation pattern.

4.To delete the entire Terminal Connection Table once set, operate:

69[X] 0 [AT/TL]

5.If a deleting operation (individual or entire deletion) is performed, the files occupied by the deleted terminal(s) (such as Floating Cashier File, etc.) are canceled. Therefore, a deleting operation should be performed only when the system is to be re-built or a terminal is to be detached from the system.

3-3

Page 191
Image 191
Toshiba FS-2600-1 Through the Keyboard In-line ID No. ST Register No. #, ST 3001 # ST 3002 #, 69 X → 0 AT/TL, Connect REG