7. BACKUP FUNCTION

EO1-11138

7. BACKUP FUNCTION

While the backup error flag is on, the following operation is performed.

The master terminal (M) gives a short beep at the timing when the long receipt is printed to warn that a backup error has occurred.

There are two timings cases the backup error flag is turned off.

1 The backup data is properly backed up according to the backup data update process. 2 The backup master terminal (ID No. 2) is deleted from the terminal connection table.

6)Backup Data Update Process

(This is a process required when the backup data stored in the backup master terminal (BM) is not updated properly due to an error.)

Backup data

M BM

Response

The method for processing the backup error is selected according to a program option setting. Even if the automatic data copy operation is selected, data copy can also be performed manually.

1 Automatic data copy

When the backup error flag is on (or turned on) , the master terminal (M) automatically sends to the backup master terminal (BM) the file in which the error has occurred, and updates the backup data.

2Manual data copy

The backup data is updated by the manual operations of the operator.

*When the backup data is being updated, inquiries from terminals may result in a “MASTER IS BUSY” error.

*When a “MASTER IS BUSY” error occurs, clear the error using the [C] key. Then, update the backup data again after the master job (backup process) is complete.

*Only the files with the backup error flag turned on are sent to the backup master terminal (BM) to update the backup data.

*When the master job is being done on the master terminal (M) ([RTR] key is turned on), backup data is not checked or updated.

7)Manual Copy of Backup Data