6. VERIFICATION OF PROGRAMMED DATA

EO1-11138

6.1 How to verify a Programmed Data through the Operator Display

6.VERIFICATION OF PROGRAMMED DATA

You can verify each data programmed in the preceding chapter. Two mode lock positions are available to verify the data; SET and X. Also two ways are available to access a programmed data you want to verify; through the operator display and through the keyboard.

6.1How to verify a Programmed Data through the Operator Display

When you turn the mode selector key to the SET or X position, the initial screen shown below will appear.

SET Mode

*SET *02-06-199903:04

1PROGRAMMING

2PROGRAM READ

3PROGRAM DLL

Please select operation by Enter key.

 

 

 

 

 

 

 

0.00

 

 

 

 

 

TOTAL

0.00

 

 

 

 

 

 

 

 

 

 

 

Pg up

 

Pg dw

 

Enter

 

 

 

 

X Mode

*X/GTX*02-06-199903:04

1X

2GTX

3PROGRAM READ

4E-JOURNAL

5OTHERS

Please select operation by Enter key.

 

 

 

 

 

 

 

0.00

 

 

 

 

 

TOTAL

0.00

 

 

 

 

 

 

 

 

 

 

 

COMB1

 

COMB2

 

COMB3

 

EJ

 

 

 

A way to access an item you want to verify is the same as that described in the section 4.1.1 How to Access a Report Item through the Operator Display (on page 4-1 in the manager’s guide) or 5.4.1 How to Access a Program Item through the Operator Display (on page 5-5 in the manager’s guide).

However, when you select “104 PLU”, the register will ask you which to choose “NORMAL” or “SIMPLE” as follows.

*X/GTX*02-06-199912:34

PROGRAM READPLU

1NORMAL

2SIMPLE

Please select operation by Enter key.

0.00

Pg up

 

Pg dw

 

Enter

 

Normal Verification

You can verify all the programmed data of a PLU table.

Simple Verification

You can verify the following data of a PLU table.

 

 

(PLU code, PLU name, tax status, link department, 1st preset price)

NOTES: 1. You can verify the following data in the address “100 MISC”. (Preset rates for the [%], [SI/TL], [CUR] keys, tax table)

2. Addresses to verify time, date, PLU stock are not provided.

6-1

Page 162
Image 162
Toshiba FS-2600-1 owner manual Verification of Programmed Data, Addresses to verify time, date, PLU stock are not provided