6. PROGRAMMING OPERATIONS

EO1-11152

6.7 PLU Table Programming (Submode 4)

6.7PLU Table Programming (Submode 4)

This submode can be operated when new PLU items are to be added, PLU program data is to be changed, or PLUs are to be deleted.

6.7.1Programming or Changing

CONDITION

 

Any time outside a sale

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPERATION

 

Mode Lock: SET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(See NOTE 2.)

 

 

 

As for details of each Address,

 

 

 

Barcode Scanning

 

 

 

 

refer to the following pages.

 

 

 

 

 

 

 

 

4 [X]

 

 

Address Numbers [#]

 

 

 

PLU Code

 

 

 

[PLU]

 

 

 

 

 

 

 

 

 

 

(See NOTE 1.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for sequential-coded item only

 

 

 

Address 1: Link Department

 

 

 

 

1 [ST]

Department Code [#]

 

 

 

 

(1 to 99)

 

 

 

Address 2: PLU Name

 

 

 

 

2 [ST]

Character Entries

[ST]

 

 

 

Max. 16 characters

 

 

 

Address 3: Preset Price

 

 

 

 

3 [ST]

Price [#]

 

 

 

 

(Max. 6 digits)

 

 

 

Address 4: Status Code 1

 

 

 

 

4 [ST]

Status Codes to ON [#]

 

 

 

Address 5: Status Code 2

 

 

 

 

5 [ST]

Status Codes to ON [#]

 

 

 

Address 6: Tax Status

 

 

 

 

6 [ST]

Status Codes [#]

 

 

 

 

(Max. 4 digits)

 

Repeat for

Repeat for

Address 7: Unit Price of Individual Split Package

 

other PLUs.

7 [ST]

Unit Price [#]

 

any address

 

 

 

(Max. 6 digits)

 

 

within the

 

 

 

 

 

 

 

same PLU by

Address 8: Whole Package Quantity

 

 

re-entry for

8 [ST]

Whole Package Quantity [#]

 

 

correction.

 

(Max. 2 digits)

 

 

(NOTE 3)

 

 

 

Address 9: PLU Group No.

 

 

 

 

 

 

 

 

9 [ST]

PLU Group No. [#]

 

 

 

 

(1 to 99; 0 to reset)

 

 

 

Address 10: Link-PLU Table No.

 

 

 

10 [ST]

Link-PLU Table No. [#]

 

 

 

 

(1 to 99; 0 to reset)

 

 

 

Address 11: Tare Table No.

 

 

 

 

11 [ST]

Tare Table No. [#]

 

 

 

 

(1 to 9; 0 to reset)

 

 

 

Address 12: Unit Weight Code

 

 

 

12 [ST]

Unit Weight Code [#]

 

 

 

 

(1 to 11; 0 to reset)

 

 

 

Address 13: Mix & Match Group No.

 

 

 

13 [ST]

Mix & Match Group No. [#]

 

 

 

 

(1 to 255; 0 to reset)

 

 

 

Address 14: Tare 2 Rate

 

 

 

 

14 [ST]

Tare 2 Rate [#]

 

 

 

 

(0.01 to 99.99%; 0 to reset)

 

 

 

Address 15: Dollar Discount/Extra Charge Code

 

 

 

15 [ST]

Dollar Discount/Extra Charge Code [#]

 

 

 

(1 to 99; 0 to reset)

 

 

 

[AT/TL]

(To complete this submode.)

 

 

 

 

6-21

 

Page 174
Image 174
Toshiba MA-1595-1 owner manual PLU Table Programming Submode, Programming or Changing