5. PROGRAMMING OPERATIONS

EO1-11152

5.2 Programming Operations Added for In-line Terminals

5.2 Programming Operations Added for In-line Terminals

5.2.1 Terminal Connection Table Setting (Submode 69)

This submode is required for In-line services. The In-line ID No., Register No. and IP Address of each terminal (including the Master Terminal) can be programmed here.

CONDITION

Any time outside a sale

OPERATION

Mode Lock: SET and IN-LINE Lamp illuminated

 

69 [@/FOR]

 

 

In-line ID No. [ST]

 

Store/Register No. [#]

 

IP Address [#]

 

 

 

 

 

 

 

2 digits (01 to 16)

 

Max. 6 digits

 

12 digits

 

 

 

 

 

 

 

 

(NOTES 1 & 2 below)

*

0 to 999999

 

(NOTE 3 below)

 

 

 

 

(NOTE 2 below)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Repeat for other terminals to be connected, including the Master Terminal itself. (Max. 16 terminals)

[AT/TL]

*For sequentially programming In- line ID Nos, the In- line ID specification can be skipped.

NOTES: 1. In-line ID No.:

Master Terminal ...

01 (fixed)

 

Backup Master Terminal (if connected) ... 02 (fixed)

 

Satellite Terminals

... 03 to 16 (max. 14 terminals)

2.The In-line ID No. and Register No. of each terminal to be set here must be the same as those programmed for the terminal in IN-LINE TERMINAL ID SETTING (Submode 77) in this chapter and STORE/REGISTER NO. SETTING (no submode) in Chapter 6 of the Programming Manual for stand-alone level.

3.IP Address: 12 digits (000.. 000 to 255.. 255)

ex) To set the IP Address 192.168.0.252……….Enter 192168000252

4.To delete an individual terminal from the Terminal Connection Table, enter 0 in place of the In- line ID No., then enter Register No..

69 [@/FOR]

 

0 [ST]

 

Store/Register No. [#]

 

[AT/TL]

 

 

 

5.To delete the entire Terminal Connection Table once set, operate:

69 [@/FOR]

 

0 [AT/TL]

 

6.If a deleting operation (individual or entire deletion) is performed, the files occupied by the deleted terminal(s) (such as Floating Cashier File, etc.) is canceled. Therefore, a deleting operation should be performed only when the system is to be re-built or a terminal is to be detached from the system.

Example)

To set Master Terminal and Satellite Terminal in the Connection

Table (total of two terminals in the in-line system):

 

Master Terminal

In-line ID No.

1

Register No.

111101

Satellite Terminal

In-line ID No.

3

Register No.

333303

Key Operation: Mode Lock SET and IN-LINE Lamp illuminated,

enter 69, depress [@/FOR].

 

 

01 [ST]

(Master In-line ID No.)

 

111101

[#]

(Master Register No.)

 

192168000251

[#]

(Master IP Address)

 

03 [ST]

(Satellite In-line ID No.)

 

333303

[#]

(Satellite Register No.)

 

192168000253

[#]

(Satellite IP Address)

 

[AT/TL]

(Complete this Submode)

 

IP Address 192.168.0.251

IP Address 192.168.0.253

TEC STORE

1343 PEACH DRIVE

PHONE: 87-6437

Open 8:00am to 7:00pm

Closed: every Wednesday

08-31-2003 SUN #3001

P69

#01 #111101 192.168. 0.251

#03 #333303 192.168. 0.253 0025 19:37TM

5- 2

Page 238
Image 238
Toshiba MA-1595-1 Programming Operations Added for In-line Terminals, Terminal Connection Table Setting Submode