360014937

WORD 89: The time period for Security Erase Unit command completion shall be set.

 

TIMER

ACTUAL VALUE

 

 

0

Not specified

 

 

1-254

( Timer ×2 ) minuites

 

 

255

> 508 minuites

 

WORD 90:

Reserved

 

 

WORD 91: Current Advanced Power Management setting

bit 15-8

Reserved

 

 

bit 7-0

Current Advanced Power Management setting set by Set Features Command.

The default value for this WORD is0080h.

WORD 92: Master Password Revision Code

the value of the Master Password Revision Code set when the Master Password was last change. Valid values are 0001h through FFFEh. A value of 0000h or FFFFh indicates that the Master Password Revision is not supported.

WORD 93: Hardware configuration test results

bit 15

0

(Fixed)

 

bit 14

1

(Fixed)

 

bit 13

1=device detected CBLID- above VIH

bit12-8

0=device detected CBLID- below VIL

Device 1 hardware reset result. Device 0 shall clear these bits to zero.

 

Device 1 shall set these bits as follows :

 

 

12

Reserved.

 

 

11

0=Device 1 did not assert PDIAG-.

 

 

 

1=Device 1 asserted PDIAG-.

 

 

10-9

These bits indicate how Device 1 determined the device number:

 

 

 

00=Reserved.

 

 

 

01=a jumper was used.

 

 

 

10=the CSEL signal was used.

 

 

 

11=some other method was used or the method is unknown.

 

 

8

1

(Fixed)

bit 7-0

Device 0 hardware reset result. Device 1 shall clear these bit to zero.

 

Device 0 shall set these bills as follows:

 

 

7

Reserved.

 

 

6

0=Device 0 does not respond when Device 1 is selected.

 

 

 

1=Device 0 responds when Device 1 is selected.

 

 

5

0=Device 0 did not detect the assertion of DASP-.

 

 

 

1=Device 0 detected the assertion of DASP-.

 

 

4

0=Device 0 did not detect the assertion of PDIAG-.

 

 

 

1=Device 0 detected the assertion of PDIAG-.

 

 

3

0=Device 0 failed diagnostics.

 

 

 

1=Device 0 passed diagnostics.

 

 

2-1

These bits indicate how Device 0 determined the device number:

 

 

 

00=Reserved.

 

 

 

01=a jumper was used.

 

 

 

10=the CSEL signa was used.

 

 

 

11=some other method was used or the method is unknown.

 

 

0

1

(Fixed)

Copyright ©2000 Toshiba corporation. All rights reserved.