360014937
BYTE 362: Off-line data collection status
Value | Definition |
00h or 80h | Off-line data collection activity was never started. |
01h | Reserved |
02h or 82h | Off-line data collection activity was completed without error. |
03h | Reserved |
04h or 84h | Off-line data collection activity was suspended by an interrupting command from host. |
05h or 85h | Off-line data collection activity was aborted by an interrupting command from host. |
06h or 86h | Off-line data collection activity was aborted by the device with a fatal error. |
07h-FFh | Reserved |
BYTE 363: Self-test execution status
The self-test execution status byte reports the execution status of the self-test routine.
Bits 0-3 (Percent Self-Test Remaining) The value in these bits indicates an approximation of the | |
percent of the self-test routine remaining until completion in ten percent increments. Valid values | are |
0 through 9. | A value of 0 indicates the self-test routine is complete. A value of 9 indicates | 90% of |
total test time remaining. | | |
Bits 4-7 (Self-test Execution Status) The value in these bits indicates the current Self-test | Execution |
Status . | | | |
| Self-test execution status values | | |
Value | Description | | |
0 | The previous self-test routine completed without error or no self-test has ever been run | |
1 | The self-test routine was aborted by the host | | |
2 | The self-test routine was interrupted by the host with a hard or soft reset | | |
3 | A fatal error or unknown test error occurred while the device was executing its self-test | |
| routineand the device was unable to complete the self-test routine. | | |
4 | The previous self-test completed having a test element that failed and the test element | |
| that failed is not known. | | |
5 | The previous self-test completed having the electrical element of the test failed. | | |
6 | The previous self-test completed having the servo (and/or seek) test element of the test | |
| failed. | | |
7 | The previous self-test completed having the read element of the test failed. | | |
8-14 | Reserved. | | |
15 | Self-test routine in progress. | | |
BYTE 364-365: Total time
The time for off-line data collection operation ( sec.)
BYTE 366: Reserve
BYTE 367: Off-line data collection capability
bit 0 | (Execute off-line immediate implemented bit) |
bit0 | = 1 | SMART EXECUTE OFF-LINE IMMEDIATE command supported. |
bit0 = 0 | SMART EXECUTE OFF-LINE IMMEDIATE command NOT supported |
This bit | is set to 1 |
bit 1 | Reserved |
bit 2 | (abort/restart off-line by host) |
bit2 | = 1 | If another command is issued, off-line data collection operation is aborted. |
bit2 = 0 | If another command is issued, off-line data collection operation is interrupted and then |
| | the operation will be continued. |
bit 3 (off-line read scanning implemented bit)
If this bit is cleared to zero, the device does not support off-line read scanning. If this bit is set to one, the device supports off-line read scanning. This bit is set to 1.
Copyright © 2000 Toshiba corporation. All rights reserved.