360014937

BYTE 362: Off-line data collection status

Value

Definition

00h or 80h

Off-line data collection activity was never started.

01h

Reserved

02h or 82h

Off-line data collection activity was completed without error.

03h

Reserved

04h or 84h

Off-line data collection activity was suspended by an interrupting command from host.

05h or 85h

Off-line data collection activity was aborted by an interrupting command from host.

06h or 86h

Off-line data collection activity was aborted by the device with a fatal error.

07h-FFh

Reserved

BYTE 363: Self-test execution status

The self-test execution status byte reports the execution status of the self-test routine.

Bits 0-3 (Percent Self-Test Remaining) The value in these bits indicates an approximation of the

 

percent of the self-test routine remaining until completion in ten percent increments. Valid values

are

0 through 9.

A value of 0 indicates the self-test routine is complete. A value of 9 indicates

90% of

total test time remaining.

 

 

Bits 4-7 (Self-test Execution Status) The value in these bits indicates the current Self-test

Execution

Status .

 

 

 

 

Self-test execution status values

 

 

Value

Description

 

 

0

The previous self-test routine completed without error or no self-test has ever been run

 

1

The self-test routine was aborted by the host

 

 

2

The self-test routine was interrupted by the host with a hard or soft reset

 

 

3

A fatal error or unknown test error occurred while the device was executing its self-test

 

 

routineand the device was unable to complete the self-test routine.

 

 

4

The previous self-test completed having a test element that failed and the test element

 

 

that failed is not known.

 

 

5

The previous self-test completed having the electrical element of the test failed.

 

 

6

The previous self-test completed having the servo (and/or seek) test element of the test

 

 

failed.

 

 

7

The previous self-test completed having the read element of the test failed.

 

 

8-14

Reserved.

 

 

15

Self-test routine in progress.

 

 

BYTE 364-365: Total time

The time for off-line data collection operation ( sec.)

BYTE 366: Reserve

BYTE 367: Off-line data collection capability

bit 0

(Execute off-line immediate implemented bit)

bit0

= 1

SMART EXECUTE OFF-LINE IMMEDIATE command supported.

bit0 = 0

SMART EXECUTE OFF-LINE IMMEDIATE command NOT supported

This bit

is set to 1

bit 1

Reserved

bit 2

(abort/restart off-line by host)

bit2

= 1

If another command is issued, off-line data collection operation is aborted.

bit2 = 0

If another command is issued, off-line data collection operation is interrupted and then

 

 

the operation will be continued.

bit 3 (off-line read scanning implemented bit)

If this bit is cleared to zero, the device does not support off-line read scanning. If this bit is set to one, the device supports off-line read scanning. This bit is set to 1.

Copyright © 2000 Toshiba corporation. All rights reserved.