360014937
10.8.33.2 | SMART Read Attribute thresholds |
| |||
|
|
|
|
| |
| COMMAND CODE | 1 0 1 1 0 0 0 0 | REGISTER | ||
|
|
| REGISTER SETTING | NORMAL COMPLETION | |
| DR |
| DRIVE No. | no change | |
| CY |
|
| C24Fh | no change |
| HD |
|
|
| no change |
| SN |
|
|
| no change |
| SC |
|
| 01h | 00h |
| FT |
|
| D1h | no change |
This command transfers attribute thresholds of the drive as 512 byte data.
Upon receipt of the command, the drive sets BSY, sets SMART data on the buffer, then, sets DRQ, resets BSY and issues an interrupt to report to the host that data transfer is ready.
Byte | Descriptions |
Data structure revision number | |
Reserved | |
511 | Data structure checksum |
BYTE
The value for this byte is 0005h.
BYTE
Individual attribute threshold data consists of 12 byte data. ( See the following fig.)
Byte | Description |
0 | Attribute ID number 01h - FFh |
1Attribute Threshold 00h= Always passed 01h= Minimum value FDh= Maximum value FEh, FFh= Not in use
Reserved |
BYTE
BYTE 511: Data structure checksum
The checksum of the first 511 byte.
Copyright © 2000 Toshiba corporation. All rights reserved.