Toshiba MK6017MAP manual 10.8.33.6, Command Code, Register Setting Normal Completion

Models: MK6017MAP

1 126
Download 126 pages 58.41 Kb
Page 101
Image 101

360014937

10.8.33.6

SMART Read Log Sector

 

 

 

 

 

 

 

 

COMMAND CODE

 

1 0 1 1 0 0 0 0

REGISTER

 

 

 

REGISTER SETTING

NORMAL COMPLETION

 

DR

 

 

DRIVE No.

no change

 

CY

 

 

C24Fh

no change

 

HD

 

 

 

 

no change

 

SN

 

Log Sector Address

no change

 

SC

 

 

 

01h

00h

 

FT

 

 

 

D5h

no change

This command returns the indicated log sector contents to the host.

Sector number indicates the log sector to be returned as described in the following Table.

Log Sector

Log sector address

Content

R/W

00h

Reserved

RO

01h

SMART error log

RO

02h-05h

Reserved

RO

06h

SMART self-test log

RO

07h-7Fh

Reserved

RO

80h-9Fh

Host vendor specific

R/W

A0h-FFh

Reserved

VS

Key

RO –Log is read only by the host.

R/W –Log is read or written by the host.

VS –Log is vendor specific thus read/write ability is vendor specific.

10.8.33.6.1 Error log sector

The following Table defines the 512 bytes that make up the SMART error log sector.

 

SMART error log sector

Byte

Descriptions

0

SMART error log version

1

Error log index

2-91

First error log data structure

92-181

Second error log data structure

182-271

Third error log data structure

272-361

Fourth error log data structure

362-451

Fifth error log data structure

452-453

Device error count

454-510

Reserved

511

Data structure checksum

10.8.33.6.2 Error log version

The value of the SMART error log version byte is set to 01h.

10.8.33.6.3 Error log data structure

An error log data structure shall be presented for each of the last five errors reported by the device. These error log data structure entries are viewed as a circular buffer. That is, the first error shall create the first error log data