3 Tests and Diagnostics 3.2 Executing the Diagnostic Test
3-4 [CONFIDENTIAL] PORTÉGÉ M500 Maintenance Manual (960-559)

3.2 Executing the Diagnostic Test

To start the DIAGNOSTIC PROGRAM, follow these steps:
1. Insert the Diagnostics disk in the USB floppy disk drive.
2. Turn on the computer while pressing U key. The following menu appears.
TOSHIBA Diagnostics Startup Menu
---------------------------------------------------------
(M) Main
(I) Initial config set
(H) Heatrun
Enter a choice: M
To start the Diagnostics menu (T&D), press M or m and Enter.
To start the H/W initial information setting tool, press I or i and Enter.
To start the Heatrun test, press H or h and Enter.
NOTE: When replacing the system board, it is necessary to execute the followings:
1. Before replacing, save the DMI information by executing subtest 03 DMI
information save in 3.3 Setting of the hardware configuration.
2. Before replacing, apply the DMI information by executing subtest 04 DMI
information recovery and subtest 08 System configuration in 3.3 Setting of the
hardware configuration.