FILE NO. SVM-07008

 

6. SPECIFICATION OF ELECTRICAL PARTS

6-1. Indoor Unit

 

 

 

 

 

 

No.

Parts name

Type

Specifications

 

 

 

 

1

Fan motor (for indoor)

AFS-220-20-4AR

AC Motor with 145°C thermo fuse

 

 

 

 

2

Thermo. sensor (TA-sensor)

 

10 kat 25°C

 

 

 

 

3

Micro power module (T101)

μRM1260V

 

 

 

 

 

4

Microcontroller unit (IC81)

μPD780076GK-703-9ET-A

 

 

 

 

 

5

Heat exchanger sensor

 

10 kat 25°C

 

(TC-sensor)

 

 

 

 

 

 

 

 

6

Line filter (L01)

SS11V-R06270

27 mH, AC 0.6A

 

 

 

 

7

Diode (D01,D02,D03 and D04)

S5688J

 

 

 

 

 

8

Capacitor (C03)

EKMH401VSN470MP20S

47μF, 400V

 

 

 

 

9

Fuse (F01)

FJL250V3.15A

3.15A, 250 V

 

 

 

 

10

Regulator IC (IC12)

S7805PIC

5VDC, 0.5A

 

 

 

 

11

Varistor (R21)

TNR10V471K-T8

470V

12

Louver motor

24BYJ48

DC 12V

 

 

 

 